Complete programming chart
D1 D2 Parameter D3 D4 Preset option Options or values
C1
Motor turning direction
01x
02
4
Opening safety device (photocell or strip)
00x
Device not installed
10
Device without testing
11
Device with testing
5
Closing safety device (photocell or strip)
Closing photocell with C520 or C521, also
prevents the start of gate opening
00x
Device not installed
10
Device without testing
11
Device with testing
20
Device without testing
21
Device with testing
8
Radio receiver
01
RSD card (non-decoding)
02x
Twin-channel decoder card
P1
Total opening radio code programming
oç
2
Pedestrian opening radio code programming
oç
3
Gate travel programming
oç
F1
Functioning mode
01
Automatic
02x
Step-by-step
2
Standby in automatic mode
0...5ÿ 0...915 59 = 59 sec.; 2ÿ5 = 2 min. 50 sec, etc
3
Pedestrian opening
00x
Pedestrian opening is not carried out
10
10% of total opening
20
20% of total opening
30
30% of total opening
40
40% of total opening
50
50% of total opening
A0
Flashing light
01x
No pre-warning
02
With pre-warning
1
Garage light time
0...5ÿ 0...903 59 = 59 secs; 2ÿ5 = 2 min. 50 secs, etc
2
Gate speed
01...503 01: minimum speed;
05: maximum speed
3
Slow down speed
01...503 01: minimum speed;
05: maximum speed
4
Slowdown distance
00...503 00: minimum distance;
05: maximum distance
5
Reverse after closing (to offset the expansion
of the gate)
A50x: stops in selected position without
making contact
A51x: makes contact and reverses back to
the selected position
0...10...904 x0: no reverse;
x9: maximum reverse
6
Maximum force
0...10...908 01: minimum force; 10: maximum force
7
Closing photocell used during standby (in
automatic mode only)
01
Immediate close
02x
Restart standby time
03
Has no effect
8
Pushbutton operation during standby (in
automatic mode only)
01
Immediate close
02x
Restart standby time
03
Has no effect
9
Opening mode
01x
Opening in accordance with the mode
selected in the main functions (F)
02
Collective opening (the control board
does not obey the key commands during
opening)
03
Step-by-step opening (the gate stops if
a key device is activated during opening.
The gate closes when operated again)
ç1
Operations carried out
XX
Indicates the hundreds of cycles
completed (for example,
68 indicates
6,800 cycles completed
)