Page 13
Notice G05 - 3 590 503
Issue: 11/2011 - Rev.A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
6 - STORAGE
6 - A - UNDER 3 MONTHS
) A sealed package (eg. heat-sealed plastic) to avoid dust and projections.
6 - B - 1 YEAR MAXIMUM
) Drain compressor oil carefully.
) Dismount the 1st and 2nd stage cylinder heads.
) Clean cylinder heads and valves carefully.
) Inject storage oil into the cylinder heads and valves.
) Mount the cylinder heads.
) Fill the compressor with storage oil.
) Start the compressor and run for 10 min off load; introduce 20cl of oil into
the compressor air intake.
) A sealed package (long term) category 4C with dehydrating packs, conforming to
S.E.I. norms.
6 - C - ABOVE 1 YEAR
Every year
) Drain storage oil carefully.
) Fill up with new storage oil.
) Start the compressor and run for 10min off load
) Start the compressor and run for 10min on load.
) A sealed package (long term) category 4C with dehydrating packs, conforming to
S.E.I. norms.