10 - F - EVERY 2000 HOURS
) Change intake and compression valves.
) Grind cylinder head if necessary.
10 - G - EVERY 3000 HOURS
) Change cooling coil assembly and shock absorber
) Change coupling blades
) Change oil plug and oil discharge plug with gaskets
10 - H - EVERY 4000 HOURS
) Check connecting rods.
) Check pistons, pistons-ring, and cylinders.
) Change cylinder head LP/HP (with valves)
10 - I - TIGHTENING TORQUE
TIGHTENING TORQUE in daN.m
- CYLINDER HEAD......................................................2.4
- CYLINDER ................................................................2.4
- OIL PIPE....................................................................1
- INTAKE PIPE.............................................................1
- BEARING ..................................................................2.4
- VALVE .......................................................................2.4 (Ø30)
- COUPLING................................................................4.7