EasyManua.ls Logo

ERVOR G05 - Preventative Maintenance; A - Every 8 Hours; B - Every 50 Hours; C - Every 200 Hours

ERVOR G05
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 24
Notice G05 - 3 590 503
Issue: 11/2011 - Rev.A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
10 - PREVENTATIVE MAINTENANCE
WORKING HOURS
10 - A - EVERY 8 HOURS
) Check the oil level.
) Drain check valve/separator using the manual drain valve.
(Not applicable in the case of automatic drain).
10 - B - EVERY 50 HOURS
) Drain the condensates from the air receiver.
) After the first 50 hours of operation drain the oil from the compressor.
10 - C - EVERY 200 HOURS
) Clean the intake air filter.
10 - D - EVERY 500 HOURS
) Discharge oil casing.
) Check intake and compression valves, clean and grind if necessary.
10 - E - EVERY 1000 HOURS
) Replace the air intake filter (reduce to 500 hours if necessary, depending on the dust/dirt level
of the compressor room).

Table of Contents

Related product manuals