4 INSTALLATION
0463 431 001
- 13 -
© ESAB AB 2016
Connection instruction
The power source is delivered with mains cable and plug connected and approved for 400 V.
If another mains voltage is required, the cable on the printed circuit board has to be moved to
the correct pin (see illustration above), and the mains cable and plug must be changed
according to relevant national regulations. This operation has to be made by persons who
have appropriate electrical knowledge. The power source must be disconnected from mains
while performing this action.