Feed L304Feed L302
Coolant
max pressure
-
-
50% water / 50% glycol
5 bar
Maximum permissible load at
60% duty cycle
100% duty cycle
365 A
280 A
365 A
280 A
Enclosure class
basic version
with sealed bobbin holder*
with MarathonPact
IP2X
IP23
IP23
IP2X
IP23
IP23
* Accessories, see page 21.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Apparatus marked IP2X are intended for indoor use.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at
a certain load without overloading. The duty cycle is valid for 40°C.
5 INSTALLATION
The installatio n must be executed by a p rofessional.
CAUTION
This product is intended for industrial use. In a domestic environment this product may
cause radio interference. It is the user's responsibility to take adequate precautions.
WARNING
When welding in an environment with increased electrical danger, only power
sources intended for this environment may be used. These power sources are
marked with the symbol