EasyManua.ls Logo

ESP aperta EZTAG3 - Lock 1 Output Operating Time; Enable Door Bell Facility

ESP aperta EZTAG3
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Enable ‘Door Bell’ Facility
Action
Step
Number
Keypad
Indication
2
Long
Tone
# #
1
2
3
4
Long
Tone
To end programming
Enter
Programming
0 2
To enable
Becomes the ‘door bell’ push in normal mode
1 2 3 4 1 2 3 4
(Default)
0 1
To disable
Lock 1 Output Operating Time
Action
Step
Number
Keypad
Indication
1
Long
Tone
# #
1
2
3
4
Long
Tone
To end programming
Enter
Programming
Enter number
of seconds 00-99
? ?
1 2 3 4 1 2 3 4
(Default)
EZTAG3 Manual_Layout 1.indd 9 18/11/2016 15:28:09