Chapter 3 Commands
■To Set the Auto Start Timer
Table 3.
36
Auto start timer setting command
Setting command
Address
Main
command
Optional
parameter
Setting data
Description/Setting data format/Example
command
<
Description
>
Sets the time of the auto start timer.
<
Setting data format
>
“time”
1 to 16 ATIME
−
Auto start
timer time
<
Example command
>
“1,ATIME,10.0”
■To Start Operations
DANGER
Before using this command, carefully read “Chapter 5
Before Use” and “Chapter 7 Operation” in the User’s
Manual – Basic Operation – and check the situation
around the chamber is completely safe. In particular,
check the following.
・
That the door is closed and locked.
・
That water in the drainage tank is higher than the low water level
but not completely full.
Table 3.37 Operation start command
Setting command
Address
Main
command
Optional
parameter
Setting data
Description/Setting data format/Example
command
<
Description
>
Starts operations.
<
Setting data format
>
“START”
1 to 16 START
−
Start
command
<
Example command
>
“1,START”
37