ETAtouch controller Getting to know the control system
21
Several views are available for each function block. To
switch between these, tap on the symbol at
the top left. The selection of views appears.
Fig. 6-2: Selection of views
1 User interface
2 Text menu
3 Inputs and outputs menu
4 Messages menu
In the user interface, you can set the most
important and common settings. For example,
adjustment of the charging times, heating
times, room temperatures and operating modes are
contained in this list. Details can be found in chapter
6.1.1 "
User interface".
The parameters of a function block are
displayed in the text menu and can be
adjusted,if necessary, see chapter 6.1.2 "
Text
menu".
The terminal assignment of individual
components, such as temperature sensors,
pumps and mixers, are visible within the input
and output menu, where they can be changed if
required. Also, for example, pumps and mixers can be
started in manual mode. This menu is intended for
specialists only. Details can be found in chapter 6.1.5
"Inputs and outputs".
Any hints, errors or faults are displayed in the
messages menu, see chapter 6.1.4
"Messages".
6.1.1 User interface
The user interface
The user interface is always displayed by default. If
you are in a different view, switch to the user view by
tapping the symbol (upper left) and then
selecting .
In the user interface, you can set the most important
and common settings. The display is dependent on the
selected function block. The illustrated example shows
the user interface of a heating circuit with a room
sensor.
Fig. 6-3: Heating circuit user interface
1 Operating condition and information
2 Producer for the heating circuit.
Currently, the buffer provides a flow temperature of
65 °C to the heating circuit.
3 On/Off switch for the heating circuit
= switched on
= switched off
4 Increase or decrease the room temperature
5 Function block settings.
In this menu, the settings and functions most
commonly used can be stored. For the heating
circuit, for example, the heating times and the
heating curve are adjusted here.
6 Graphic display of the heating times and room tem-
peratures settings
7 Different operating modes of the heating circuit

Table of Contents