24-Port Web-Smart Ethernet Switch
User’s Manual
9
Installation
Selecting a Site for the Equipment
As with any electric device, you should place the equipment where
it will not be subjected to extreme temperatures, humidity, or
electromagnetic interference. Specifically, the site you select
should meet the following requirements:
- The ambient temperature should be between 0 to 45 degrees
Celsius.
- The relative humidity should be less than 95 percent,
non-condensing.
- Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards for IEC 801-3, Level 2
(3V/M) field strength.
- Make sure that the equipment receives adequate ventilation.
Do not block the ventilation holes on each side of the switch or
on the rear of the equipment.
- The power outlet should be within 6 feet (1.8 meters) of the
switch.