KL8-3H-CAA6/KL8-3H-BAA6
www.ethink
-
spa.com
8
every timeworking time is 30 seconds ozone work for 15 minutes15 minutes for clearance
Water surf PUMPS and BLOWER is turned onozone can not workcirculating pump is turned
offthe ozone can not work
13 the bottom light steps:
The first by Key to open the underwater lightsthe color slowly changes the second
time by The color of the current fixed the third time by The closure of the
underwater lights
14constant temperature heating steps:
1), in the pre-heating time to the pre-heating case opened or by Key can be turned on the
heating system thermostat
2When heating the normal opening for the time by Key to open the heaterthe
circulation pump will work automatism
3)heating thermostat open the furnace is turned on when the thermostat has been circulating
pump rotation
4)such as temperature set to 35 when the temperature reached or exceeded 36 the
heater shut down 5 seconds after circulating pump will stop working (cleaning pump did not start the
case) and when the water temperature at or below 34 circulating pump restart and re-open the
heater
15the operation of blower:
Button Control of the wind pump on / off
Blower is activatedas in the absence of circumstances the work of 20 minutes will be
automatically closed
16Fahrenheit and Celsius temperature switch:
In the waiting state by Buttonthe temperature in Fahrenheit and Celsius temperature
switch
17when the pool water, the three-way water pump and thermostat systems are not
activated, but the LCD display on the corresponding symbol will be flashing.
18Frozen preventing control function
When the water temperature below 5 the heater and circulation pump will automatically start
the water heating when the water reached 10 the heating stopped
This function must ensure that the normal power supply
19power control functiononly of KL8-3H-BAA6
There are one power control modes PC1 the latter priority
Power control all the high-voltage load is divided into two groupsone for Aheater + circulating
pumpand the other group Bsurf pumps+ blower
1), PC1 the latter priority mode
When opening Group A or B in any one of the loadand load a group of self-closingsuch
as open PUMP1heater and circulating pump shut down automaticallythe same tokenopen
the heatingThe surfing pumps and blower shut down automatically
2), Setting of power control mode