Cleaning And Maintenance
06
Disconnect the power supply before cleaning, and wipe the inner and outer surfaces of the
refrigerator with a cleaning cloth dipped with an appropriate amount of water or detergent. It is
not allowed to wash with water directly to avoid damage to the electrical components. When the
refrigerator is not used for a long time, it is necessary to clean the inside and outside of the
refrigerator and keep it dry. Always take moisture-proof and dust-proof measures to avoid mildew
and peculiar smell inside the refrigerator.
Error Code Description
When the compressor, module, fan and temperature sensors are abnormal and the input voltage is
too low, the error code will appear on the display screen, and the compressor will stop working.
After the abnormality is eliminated, unplug the power supply and plug it in again. The temperature
in the refrigerator can be displayed normally, and the compressor cooling mode will start to work
after 1 minute.
The code description is shown in the table below:
Problem Error
E 0
The temperature sensing head
is damaged
Input voltage is too low
DC fan over current protection
Abnormal start of compressor
Abnormal compressor speed
Module temperature too high
Please check or replace the
temperature sensor
Please check the input voltage and
adjust the battery protection level
Please check the cooling fan
Please turn off the power and let it
stand for 30 minutes
Please adjust compressor operation
mode (MAX/ECO)
Please move the refrigerator to a
ventilated place to lower the module
temperature
E 1