l System guided walk test with report - "Force call" feature for simple remote tech. support.
l Bell & Auxiliary fuse monitoring - Low/missing battery monitoring - Mains fail and restore
indication.
l 2 x on-board fused bell/siren outputs - 4 x on-board open collector outputs for digital
communicator, etc.
General Features
The Verifier 24/64 offers 2 types of system operation - STANDARD (Commercial/Domestic) and
BLOCK system.
l Commercial/Domestic System - The standard system can be set for either Commercial or
Domestic mode. In Commercial mode the setting modes appear as PARTGUARD A,
PARTGUARD B and FULL SET. In Domestic mode they appear as HOME, NIGHT and FULL SET.
(see p.2-1 for an explanation).
l Block System - The Verifier can also be subdivided into a Block system. Block C is a common
area and will not arm until both Block 1 and 2 are fully armed. This is typically used in office
complexes but can have domestic applications as well (see "System Expansion"). Verifier 24
allows for 2 separate blocks, Verifier 64 allows for 4.
l On-board zones - There are 8 on-board zone inputs provided, with a common terminal for
each zone pair. These inputs are dual End Of Line monitored loops, and use 1KOhm resistors
across the zone contacts.
l Multiplex Data Line Connection - A further 16 zones (56 on the Verifier 64) may be added to
the system by connecting Line Encoder Modules (LEMs), Input/Output modules or a
combination of both to the Multiplex Data Line.
l Remote Keypads- Up to 16 addressable Remote Keypad Displays may be connected to
the Multiplex Data Line.
l True Split System - The Verifier 24/64 boasts a TRUE two-way SPLIT system. This feature allows
each tenant the luxury of a completely independent system under the control of one
multiplex panel. True split implies that each tenant has their own RKD, access codes etc.
and is completely oblivious to the system functionality of the other split system. Either system
type may be assigned to a split, thus permitting various combinations such as Split 1 =
Commercial, Split 2 = Domestic ; Split 1 = Block, Split 2 = Commercial, etc. (see "System
Expansion").
l 16 Users - In addition to the Engineer and Master User (s), the system allows up to 16 general
users to be defined (32 users on the VERIFIER 64 ). Each user is identified by name, and can
have a flexible level of access.
l 250 Event Log - The system’s 250-event log (up to 500 on the VERIFIER 64) records each
event/action, user name, and is timed to the second.
Introduction
ii