Do you have a question about the Europlex 3GS and is the answer not in the manual?
Explains the 3rd Generation System (3GS), its patented ringnet topology, and key features.
Details essential procedures for IEE regulations, powering, EOL resistors, default codes, and ringnet wiring.
Details the main components: Control Panel, PSU, Nodes, and Hand Held Terminal (HHT).
Illustrates a typical system configuration diagram showing controller, nodes, and peripherals.
Explains node wiring, cable types, maximum distances, and environmental considerations for ringnet.
Provides critical pre-power up checks, grounding, polarity, and power connection guidelines.
Describes the controller unit, its software, inputs, outputs, and serial ports for system operation.
Details the components and connections on the 3GS controller Printed Circuit Board (PCB).
Illustrates the internal layout and sizes of the metal cabinet for the 3GS controller and PSU.
Lists the supported 3GS nodes and their general functionalities, including RKD, I/O, and Access Control.
Details the RKD node's features, LED indicators, ringnet communications, and input capabilities.
Describes the I/O node's 8 input zones, 1 relay output, and auxiliary supply specifications.
Explains the ACN's interface for door access control, reader support, and system integration.
Provides security for zone inputs using encrypted modules and incorporates 8 Input/1 Output node features.
Explains navigation using the RKD keypad, including mode keys, display, and numeric entry methods.
Details assigning alphanumeric descriptions (up to 24 characters) for zones and doors for identification.
Covers setting zone types and attributes, and mapping outputs to zones for expanded functionality.
Explains how different zone types affect reporting and system behaviour based on assigned attributes.
Defines attributes like Inhibit, Exit, Access, Push, Fire-X, Xshunt, Xtamper, Panic, Day-PA, KeyArm, 24 HR, Set/Arm, Unset Local, Double Knock, Fire.
Introduces the HHT as a compact device for system communication, status extraction, and data transfer.
Explains HHT power-up, code entry, and navigation through RKD Emulation, Data Buffer, and Utilities modes.
Allows control, programming, and interrogation of the 3GS system via IR link or serial connection.
Enables management and transfer of 3GS literal files, including upload, download, and file management.
Provides output mapping functions for the 3GS controller, used for CCTV and security peripherals.
Details the serial connection procedure between the EUIC and the 3GS controller for system communication.
Explains PC connection using a null modem cable and setting communications parameters for EUIC software.
Guides on installing the EUIC programming application and using Hyper Terminal for configuration.
Describes the DM1200 as a 16-channel digital communicator and 1200 baud modem for alarm reporting.
Covers BABT approval, power supply requirements, and PSTN connection details for the DM1200.
Provides a checklist for programming the DM1200 for digi and modem reporting, and flowcharts for setup.
Details the Europlex RS232/422 Network Router for connecting multiple 3GS panels via RJ45 connections.
Illustrates typical connection diagrams for PCs, modems, and multiple 3GS controllers via the router.
Describes the IntelliBell for interfacing with 3GS, its functions, and reporting capabilities.
Illustrates wiring for IntelliBell connection, programming, default settings, and event reporting.
Details the programming menu, log messages, and output functions for the IntelliBell unit.
Provides detailed technical specifications for the 3GS Controller, including grade, dimensions, and interface details.
Lists technical specifications for the 3 Amp PSU, including fuses, voltage, and efficiency.
Details technical specifications for the 4 Amp and 6 Amp PSUs, including fuses and voltage.
Provides technical specifications for the RKD Node, including grade, dimensions, and keypad features.
Lists technical specifications for the Access Control Node, including grade, fuses, and communication.
Details the features of 3GS+ software for installers, including card management and reporting.
Provides step-by-step instructions for installing the 3GS+ software and its drivers.
Guides on installing the HASP device driver for the security dongle required for 3GS+ operation.
Outlines the steps involved in upgrading from 3GS+ 1.17/1.17a to 3GS+ 2.0.
Introduces 3GS Panelman for Windows as a programming tool for the 3GS Control System.
Highlights key features of Panelman 3GS, including zone/output control and remote communications.
Specifies the software, CPU, memory, storage, and dongle software needed for Panelman installation.
Provides step-by-step instructions for installing Panelman for Windows from the CD.
Guides on logging into Panelman, creating accounts/installations, and navigating the interface.
Describes CiTeC II as a dual signalling device interfacing with 3GS/Aplex for central station communication.
Details general requirements for alarm systems, including levels of access and Europlex conformity.
Covers control and indicating equipment requirements, including entry/exit time limitations.
Explains processing of alarm and tamper fault messages and Europlex conformity for signal processing.
Details alarm transmission warning requirements and Europlex conformity for Class IV systems.