3GS Integrated Security Solution
Technical Manuals
Technical Manuals
Introduction to 3GS
3GS Hardware
3GS Programming
3GS User Guide
3GS Peripherals
3GS Technical Specifications
and PC software
3GS
Integrated Security Solution
Technical Manuals
Introduction to 3GS
3GS Hardware
3GS Programming
3GS User Guide
3GS Peripherals
3GS Technical Specifications & PC Software

Table of Contents

Other manuals for Europlex 3GS

Question and Answer IconNeed help?

Do you have a question about the Europlex 3GS and is the answer not in the manual?

Summary

3 GS System Overview

What is 3 GS?

Explains the 3rd Generation System (3GS), its patented ringnet topology, and key features.

Installation Guidelines

Details essential procedures for IEE regulations, powering, EOL resistors, default codes, and ringnet wiring.

3 GS Hardware Overview

System Components

Details the main components: Control Panel, PSU, Nodes, and Hand Held Terminal (HHT).

System Configuration

Illustrates a typical system configuration diagram showing controller, nodes, and peripherals.

Ringnet Communications

Explains node wiring, cable types, maximum distances, and environmental considerations for ringnet.

Before Powering Up

Provides critical pre-power up checks, grounding, polarity, and power connection guidelines.

Controller

3 GS Controller Overview

Describes the controller unit, its software, inputs, outputs, and serial ports for system operation.

Controller PCB

Details the components and connections on the 3GS controller Printed Circuit Board (PCB).

Controller Cabinet

Illustrates the internal layout and sizes of the metal cabinet for the 3GS controller and PSU.

Nodes

Nodes Overview

Lists the supported 3GS nodes and their general functionalities, including RKD, I/O, and Access Control.

Remote Keypad Display (RKD) Node

Details the RKD node's features, LED indicators, ringnet communications, and input capabilities.

8 Input;1 Output (I;O) Node

Describes the I/O node's 8 input zones, 1 relay output, and auxiliary supply specifications.

Access Control Node (ACN)

Explains the ACN's interface for door access control, reader support, and system integration.

Encryption Node

Provides security for zone inputs using encrypted modules and incorporates 8 Input/1 Output node features.

Programming Menus

Menu Navigation

Explains navigation using the RKD keypad, including mode keys, display, and numeric entry methods.

Zones;Doors;Vars - Descriptions

Details assigning alphanumeric descriptions (up to 24 characters) for zones and doors for identification.

Zones;Doors;Vars - Options

Covers setting zone types and attributes, and mapping outputs to zones for expanded functionality.

Zone Types

Explains how different zone types affect reporting and system behaviour based on assigned attributes.

Zone Attributes

Defines attributes like Inhibit, Exit, Access, Push, Fire-X, Xshunt, Xtamper, Panic, Day-PA, KeyArm, 24 HR, Set/Arm, Unset Local, Double Knock, Fire.

Hand-Held Terminal (HHT)

HHT Overview

Introduces the HHT as a compact device for system communication, status extraction, and data transfer.

Main Menu

Explains HHT power-up, code entry, and navigation through RKD Emulation, Data Buffer, and Utilities modes.

RKD Emulation Mode

Allows control, programming, and interrogation of the 3GS system via IR link or serial connection.

Data Buffer (Filesaver) Mode

Enables management and transfer of 3GS literal files, including upload, download, and file management.

Europlex Universal Interface Card

EUIC Overview

Provides output mapping functions for the 3GS controller, used for CCTV and security peripherals.

Connecting the EUIC to the 3 GS Controller

Details the serial connection procedure between the EUIC and the 3GS controller for system communication.

Connecting the EUIC to the PC

Explains PC connection using a null modem cable and setting communications parameters for EUIC software.

EUIC Programming Software

Guides on installing the EUIC programming application and using Hyper Terminal for configuration.

DM1200 Digital Communicator;Modem

DM1200 Overview

Describes the DM1200 as a 16-channel digital communicator and 1200 baud modem for alarm reporting.

DM1200 Installation

Covers BABT approval, power supply requirements, and PSTN connection details for the DM1200.

DM1200 Programming

Provides a checklist for programming the DM1200 for digi and modem reporting, and flowcharts for setup.

Network Router

Network Router Overview

Details the Europlex RS232/422 Network Router for connecting multiple 3GS panels via RJ45 connections.

Sample Connection Diagram & Scenarios

Illustrates typical connection diagrams for PCs, modems, and multiple 3GS controllers via the router.

IntelliBell

IntelliBell Overview

Describes the IntelliBell for interfacing with 3GS, its functions, and reporting capabilities.

IntelliBell Connection Diagram

Illustrates wiring for IntelliBell connection, programming, default settings, and event reporting.

IntelliBell Programming

Details the programming menu, log messages, and output functions for the IntelliBell unit.

Technical Specifications

3 GS Controller

Provides detailed technical specifications for the 3GS Controller, including grade, dimensions, and interface details.

3 Amp Power Supply Unit

Lists technical specifications for the 3 Amp PSU, including fuses, voltage, and efficiency.

4 Amp Power Supply Unit

Details technical specifications for the 4 Amp and 6 Amp PSUs, including fuses and voltage.

RKD Node

Provides technical specifications for the RKD Node, including grade, dimensions, and keypad features.

Access Control Node

Lists technical specifications for the Access Control Node, including grade, fuses, and communication.

PC SOFTWARE

3 GS+ Overview

Details the features of 3GS+ software for installers, including card management and reporting.

Installing 3 GS+

Provides step-by-step instructions for installing the 3GS+ software and its drivers.

Installing the Dongle

Guides on installing the HASP device driver for the security dongle required for 3GS+ operation.

Upgrading

Outlines the steps involved in upgrading from 3GS+ 1.17/1.17a to 3GS+ 2.0.

Panelman 3 GS

3 GS Panelman for windows Overview

Introduces 3GS Panelman for Windows as a programming tool for the 3GS Control System.

Features

Highlights key features of Panelman 3GS, including zone/output control and remote communications.

System Requirements

Specifies the software, CPU, memory, storage, and dongle software needed for Panelman installation.

Installation

Provides step-by-step instructions for installing Panelman for Windows from the CD.

Getting Started

Guides on logging into Panelman, creating accounts/installations, and navigating the interface.

CiTeC II Installation

Introduction to CiTeC II

Describes CiTeC II as a dual signalling device interfacing with 3GS/Aplex for central station communication.

Class IV Method Statement

EN50131 -1 Alarm systems - Intrusion systems - Part 1: General requirements

Details general requirements for alarm systems, including levels of access and Europlex conformity.

EN50131 -3 Alarm systems - Intrusion systems - Part 1: Control and Indicating equipment.

Covers control and indicating equipment requirements, including entry/exit time limitations.

Alarm Transmission warning requirements

Explains processing of alarm and tamper fault messages and Europlex conformity for signal processing.

EN50131 -3 Paragraph 8.2.4.4 Class IV Page 22

Details alarm transmission warning requirements and Europlex conformity for Class IV systems.

Europlex 3GS Specifications

General IconGeneral
BrandEuroplex
Model3GS
CategoryControl Panel