EVCO S.p.A. Vcolor 869/879 | Installer manual ver. 2.2 | Code 144VC869E214
page 66 of 94
13.1.4 Downloading configuration param. settings (controller -> USB)
To download the settings of the configuration parameter, operate as follows:
1. Make sure the device is in stand-by and no procedure is underway;
2. Insert the USB flash drive into the USB port and wait until the menu is displayed;
3. Touch “DOWNLOAD PARAMETERS”;
4. When the upload is complete, remove the USB flash drive from the device USB port.
13.1.5 Downloading HACCP data (controller -> USB)
To download the HACCP data, operate as follows:
1. Make sure the device is in stand-by and no procedure is underway;
2. Insert the USB flash drive into the USB port and wait until the menu is displayed;
3. Touch “DOWNLOAD HACCP DATA”;
4. Select date and hour of start for historical data recording ;
5. Touch to confirm. A file named “haccp.csv” will be generated;
6. When the download is complete, remove the USB flash drive from the device USB port.
If the language in use is not a Western alphabetic language, data are saved in English in the "haccp.csv" file.
For a better view of the “haccp.csv” file we recommend using OpenOffice and proceeding as follows:
1. With the right mouse button select the Open with OpenOffice Calc option.
2. The following screen will appear:
3. Select Unicode (UTF-8) as the character type, select the language in which you downloaded the data and
press the OK button.