EasyManua.ls Logo

Evco c-pro 3 micro CHIL Series - User Manual

Evco c-pro 3 micro CHIL Series
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EVCO S.p.A.
c-pro 3 micro CHIL | Application manual ver. 1.0 | Codice 144CP3CHE104
c-pro 3 micro CHIL
Programmable controllers for single-and
two-circuits chillers-heat pumps
Application manual | ENGLISH
Codice 144CP3CHE104
Question and Answer IconNeed help?

Do you have a question about the Evco c-pro 3 micro CHIL Series and is the answer not in the manual?

Evco c-pro 3 micro CHIL Series Specifications

General IconGeneral
BrandEvco
Modelc-pro 3 micro CHIL Series
CategoryController
LanguageEnglish

Summary

3. Hardware Solutions

5. User Interface

6.1 Password

Explains the password system for accessing different menu levels and functions, ensuring secure operation.

6.8 Installer Menu

Covers the Installer Menu (Level 3) for configuring functionalities, alarms, and settings of the machine.

6.9 Constructor Menu

Explains the Constructor Menu (Level 4) for machine configuration, I/O settings, and advanced parameters.

7. Parameters List

7.1 List of Configuration Parameters

Lists all configuration parameters with their codes, descriptions, default values, and menu access paths.

8. Regulations

8.4 Operating Mode Control

Explains how to set and change the unit's operating mode (Chiller/Heat Pump) through various procedures.

8.6 Compressor Control

Details the compressor control types: lateral-band and zero energy band, with operational logic.

8.7 Compressor Management

Covers compressor status, rotation procedures, and protection timings for reliable operation.

8.8 Condenser control

Explains condenser control methods including modulating and single-stage fan control for pressure regulation.

8.12 Defrosting Management

Covers the defrosting procedure for heat pump units, including activation, interruption, and dripping time.

8.15 Free-Cooling Management

Details the free-cooling function for energy savings, including enabling, regulation, and control valve operation.

8.16 Temperature Alarm Control

Manages low and high temperature alarms, including set points, delays, and management modes.

8.17 Pressure Alarm Control

Covers high-pressure, low-pressure, and transducer alarms, detailing their management and reset procedures.

9. Wiring Diagram

10. Diagnostics

10.1 Manual and Automatic Alarms

Differentiates between manually and automatically resetting alarms and their management.

10.4 Alarm Table

Provides a comprehensive list of all managed alarms, their types, consequences, and relevant parameters.

11. List of Modbus Variables

Related product manuals