5
EASY DECISION
OPERATING INSTRUCTIONS
There are five touch buttons:
Low Fan
Medium Fan
High Fan
Light
Power
1. Press the power button to turn the rangehood on or off.
2. Press the ‘Low’ button to set the fan to low speed.
3. Press the ‘Medium’ button to set the fan to medium speed.
4. Press the ‘High’ button to set the fan to high speed.
5. Press the light button to turn the light on or off.
TROUBLESHOOTING
Fault
Possible Cause
Solution
Light on, but
motor does not
work
Fan switch turned off
Select a fan switch position.
Fan switch failed Contact Service Department.
Motor failed
Contact Service Department.
Light does not
work, motor
does not work
House fuses blown
Reset/Replace fuses.
Power cord loose or disconnected
Refit cord to power outlet.
Switch power outlet on.
Oil leakage
One way valve and the air ventilation
entrance are not tightly sealed
Take down the one way valve and seal with
sealant.
Leakage from the connection of U-
shaped section and cover
Take U-shaped section down and seal.
Lights not
working
Broken/Faulty globes Contact Service Department.
Insufficient
suction
The distance between the range hood
and the gas top is too far
Refit the range hood to the correct distance.
The Range hood
inclines
The fixing screw not tight enough
Tighten the hanging screw and make it
horizontal.