32
Using Your Evinrude E-TEC Outboard
Engine Starting
Turn the key switch fully clockwise to the
START position.
The starter motor can be dam-
aged if operated continuously for more
than 20 seconds.
Upon start-up, release the key.
If the engine did not start, release the key mo-
mentarily, then try again.
Each time the key switch is turned from OFF
to ON, the warning system will self-test. Refer
to Engine Monitoring on page 43. If the
warning system fails to self-test during start-
up, see your Dealer.
If your outboard does not react normally to
this starting procedure or if it fails to start, re-
fer to Troubleshooting on page 62.
After Engine Starts
Check the water pump indicator. A steady
stream of water indicates the water pump is
working. If a steady stream of water from the
water pump indicator is not visible, stop the
engine. Refer to Engine Overheating on
page 43.
Engine Stopping
Move control handle to NEUTRAL.
Turn key switch counterclockwise to the OFF
position.
Remove the key when the boat will be unat-
tended.
007015
NOTICE
1. Water pump indicator
007016
1. Key switch, OFF position
007072
1
1
Key
OFF
ON
START

Table of Contents