Overcurrent
Protection
Flashing red 6
times
3 seconds interval
OCP (Overcurrent
Protection) Fault.
OCP Fault is triggered
when the current is over
110% of rated current
set. For example for
48A set on the EV
Charger ,OCP is
48A*1.1=53A. The value
of the overcurrent shall
be calculated based on
the rated current set
through the Amperage
Dial Switch inside the
EV charger, e.g. if the
current Amperage Dial
Switch is set for 2, the
rated current will be
40A, then the OCP is
110%*40A=44A. For
more information about
the Amperage Dial
Switch - go to page
11-12 of this Guide.
a) Unplug the J1772 connector.
b) The device will recover
automatically when the current
goes down to a normal range.
Reconnect the charger to the EV
car for further normal use.
Ground Wire
Disconnected
Flashing red 7
times
3 seconds interval
Ground wire not
connected
a) Unplug the J1772 connector.
b) Please contact an electrician
to make sure the PE (Protective
Earthing) line is properly
connected.
c) In case the device is
hardwired, please make sure the
input Live line and Neutral line
(L1 and L2 lines) are not
inversely connected.
d) The device will recover
automatically when it comes to
normal.
If this fault occurs during
charging, remove the connector
after the ground line is properly
connected.
Relay Fault
Flashing red 8
times
3 seconds interval
Relay failure during
charging
a) Unplug the J1772 connector
and reboot the charger if the
problem persists after the
unplugging.
b) Avoid prolonged simulator or
eviqo.io 28