Starting Generator
EVO2000i+ Models: Depress the primer bulb
3 times to supply fuel to start the engine.
12.
is green and stays on.
FIGURE 11: Prime Engine
NOTE:
INITIAL START: Depress the primer bulb 30-50 times to
prime the fuel lines and fill the carburettor loat bowl.
NOTE:
If the generator has a low fuel tank or has been run to
be depressed 30-50 times to prime the fuel lines and
carburettor loat bowl.
FIGURE 13: Output Ready Indicator Light (EVO1000i model)
13. Allow the engine to run continuously and warm up
before connecting any appliance.
NOTICE
If the engine stops and will not restart, check the engine oil
level before troubleshooting in other areas.
9. While securing the generator with one hand, grip the
recoil starter handle and pull slowly until you feel
slight resistance. (EVO2000i model illustrated)
FIGURE 12: Recoil Starter Handle
10. Apply 1 to 4 swift pulls to start the engine, carefully
returning the recoil starter handle to the original
position.
NOTICE
To prevent damage to the generator, do not allow the recoil
starter handle to snap back against the engine.
11. After the engine starts, let run for 2-5 seconds and
then slowly move the choke to the RUN position.
EVO1000Si / EVO2000Si / EVO2000SEi / EVO3000Si / EVO3000SEi Inverter Generator Owner’s Manual www.evopower.co.uk 12