MAINTENANCE
Maintenance Schedule
Periodic maintenance and adjustment are necessary to keep the generator in good operating condition. Perform service and
inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3).
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
WARNING
Accidental starting of generator can cause severe injury or
death. Before performing maintenance, disconnect spark
plug cap from spark plug.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and far
away from windows, doors, and
vents.
WARNING
Improper maintenance, or failure to correct a problem
before operation, can cause a malfunction in which you
can be seriously hurt or killed. Always follow inspection
and maintenance recommendations and schedules in this
owner's manual.
Shut off engine before performing any maintenance.
If engine must be run, be sure area is well ventilated.
NOTICE
Maintenance, replacement, or repair of the emission
control devices and systems may be performed by any
non-road engine repair establishment or individual.
NOTICE
The maintenance schedule applies to normal operating
conditions. If you operate generator under severe
conditions, such as sustained high-load or high-
temperature, or use it in unusually wet or dusty conditions,
consult your servicing dealer for recommendations
applicable to your individual needs and use.
MAINTENANCE TASK
FREQUENCY*
Before
each use
First month
or 25 hours
of use
Every 3
months or
50 hours of
use
Every 4
months or
62.5 hours of
use
Every 6
months or
100 hours of
use
Every
year or
200 hours
of use
Fill fuel tank
X
Check engine oil level
X
Check air cleaner
X
Clean air cleaner
X
Change engine oil (EVO1000i)
X
Change engine oil (EVO2000i+)
X
Check/clean spark plug
X
Clean spark arrestor
X
Check/adjust valve clearance
X**
Clean fuel tank and strainer
X**
Check fuel line
Every 2 years (replace if necessary)**
TABLE 3. Generator Maintenance Schedule
Clean more often when using generator in dusty areas.
EVO2000i+ models only.
** It is recommended that this maintenance task be performed by a service dealer.