10
Cutting height max. ..................... 85 mm / 90°
.............................................. 65 mm / 45°
Tilting saw blade ...................... infinite 0 - 45°
Extractor socket ............................... Ø 35 mm
Weight ....................................... approx. 22 kg
Operating mode S6 25%: Continuous operation
with idling (cycle time 10 minutes). To ensure
that the motor does not become excessively hot,
it may only be operated for 25% of the cycle at
the specified rating and must then be allowed to
idle for 75% of the cycle.
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 61029.
LpA sound pressure level ............... 91 dB(A)
KpA uncertainty ........................................ 3 dB
LWA sound power level ................. 104 dB(A)
KWA uncertainty ....................................... 3 dB
The quoted values are emission values and not
necessarily reliable workplace values. Although
there is a correlation between emission and
immission levels it is impossible to draw any
certain conclusions as to the need for additional
precautions. Factors with a potential influence
on the actual immission level at the workplace
include the duration of impact, the type of room,
and other sources of noise etc., e.g. the number
of machines and other neighboring operations.
Reliable workplace values may also vary from
country to country. With this information the user
should at least be able to make a better
assessment of the dangers and risks involved.
Wear ear-muffs.
The impact of noise can cause damage to
hearing.
Keep the noise emissions and vibrations to a
minimum.
• Only use appliances which are in perfect
working order.
Service and clean the appliance regularly.
• Adapt your working style to suit the appliance.
• Do not overload the appliance.
• Have the appliance serviced
whenever necessary.
• Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain
residual risks cannot be rules out. The
following hazards may arise in connection
with the equipment’s construction and
layout:
1. Lung damage if no suitable protective
dust mask is used.
2. Damage to hearing if no suitable ear
protection is used.
7. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating
plate are identical to the mains data.
Warning! The maximum permissible system
impedance is 0.340Ω at the interface point of the
user’s supply. The manufactory should declare
it in the equipment instruction manual and
instruct the user to determine in consultation
with the supply authority, if necessary, that the
equipment is connected only to a supply of that
impedance or less.
Warning!
Always pull the power plug before making
adjustments to the equipment.
• Unpack the bench-type circular saw and
check it for damage which may have occurred
in transit.
• The machine has to be set up where it
can stand firmly, e.g. on a work bench, or it must
be bolted to a strong base.
• All covers and safety devices have to be
properly fitted before the machine is switched
on.