Page #10 background imageLoading...
Page #10 background image
02025100 ZSME300000340
9
EXCELL PRECISION CO., LTD.
Last Page
Hold function setting
Use ON|ZERO or UNITS1 key to enter a parameter
0 Hold function disabled
1 Peak hold mode
2 Stable hold 1 mode
3 Stable hold 2 mode
Use ON|ZERO or UNITS1
to enter a parameter
Weighing mode
Press
TARE
key to
complete function setting
Press
TARE
key
Hold function setting
The display shows the current setting
ON|ZERO key Upward key (from 0 to 9)
UNITS1 key Downward key (from 9 to 0)
TARE
key Confirm / enter key
NET|GROSS key Move the cursor to left.
= Hold function disabled
= “Peak hold” mode
The scale shows the maximum weight value detected from
the continuously changing weight values. Press any key to
exit the hold function.
= Stable hold 1 mode
After the scale is stable, the display shows the current weight
value. Press any key to exit the hold function.
= Stable hold 2 mode
After the scale is stable, the display shows the current weight
value. Re-zero the scale to exit the hold function.