02025100 ZSME300000340
EXCELL PRECISION CO., LTD.
Use ON|ZERO or UNITS1
to enter a parameter
Use ON|ZERO or UNITS1
to enter a parameter
Chapter 2 Advanced Function Setting
In weighing mode, press NET|GROSS and ON|ZERO keys at the same time to enter the
Advanced Function setting mode. The display shows .
Auto power off timer setting
Use ON|ZERO or UNITS1 key to enter a parameter
0 No auto power off
1 When the scale is idle for 1 minute, the scale
auto power off.
2 When the scale is idle for 2 minutes, the scale
auto power off.
……..
19 When the scale is idle for 19 minutes, the scale
auto power off.
Auto power off timer setting
The display shows the current setting
Auto backlight setting
The display shows the current setting
Auto backlight setting
Use ON|ZERO or UNITS1 key to enter a parameter
on Auto backlight on
off Auto backlight off
ON|ZERO key Upward key (from 0 to 9)
UNITS1 key Downward key (from 9 to 0)
TARE
key Confirm / enter key
NET|GROSS key Move the cursor to left.
Auto power off
When the weight on weigh pan is less than 10d or remains steady for the set time,
the scale will automatically power off.
Auto power off is not functional, when using AC adaptor as power source.
Therefore, auto power off is ONLY active, when using dry batteries as power source.
Auto backlight
When the weight is over 10d, the display backlight will be on. After the weight is
stable for 10 seconds or when the scale returns to zero, the display backlight
switches off.