29
MANUGENEX7xx - Version 2.09
© 2018-2020 EXOR International S.p.A. - Subject to change without notice
10 System Settings
Activation of Systems Settings in System Mode:
Normal operation If JMobile runtime is not running: Press “System Setting” button on
the device screen to recall System Settings in User Mode. Select
“Restart” -> “Cong OS” to reboot in System Mode.
If JMobile runtime is running: recall context menu and select
“System Settings”. To recall the context menu click and hold any
unused area of the touchscreen for a few seconds. Default hold
time is 2 seconds to enter in System Settings in User Mode. Select
“Restart” -> “Cong OS” to reboot in System Mode.
Recovery operation If device is not responsive, use the so-called “tap-tap” procedure.
This procedure consists in tapping the surface of the touchscreen
during the device power-up phase. Tapping frequency must be high.
You have to start tapping the touchscreen as soon as power has been
applied to the device. When the sequence has been recognized, the
system shows the message: “TAP-TAP DETECTED”. At this point
release touch to boot in User Mode without running JMobile runtime
or press and hold few seconds (selecting so “RESTART: CONFIG
OS”) to boot in System Mode.
System Settings includes options for basic settings of the device:
Language Congure language used for System Setting menu only.
System Show information about platform, status and timers (like System on
time, backlight on time).
Logs Enable persistent log for BSP and allows exporting it.
Date & Time Change the device date and time, including time zone and NTP
Server
Network Congure IP Address of Ethernet interface and the other network
settings like DNS, Gateway, DHCP, Hostname, routing and
bridging.
Services Enable/disable services. Examples of services are: OpenSSH
server, Bridge, Cloud, Router, SNMP and logging.
Management Update of BSP components (Main OS, Cong OS, Boot loader,
XLoader), check for partitions consistence, update of splash
screen, information about usage and size of partitions. The
update of Main OS is available only in System Mode, the update
of Cong OS is only in User Mode.
Display Adjust display brightness, congure automatic backlight turnoff
and select HMI orientation (90°, 180°, 270° and 360°).
Restart Restart the device. “Main OS” option restarts the device in User
Mode, “Cong OS” option restarts the device in System Mode
showing System Settings.
Authentication Congure password for administrator (“admin”) and for the standard
user (“user”). Administrator has full access to System Settings
(updates of BSP and other system components). Standard user has
some limitations.
Note: Additional informations on System Settings are available in dedicated manual.