Symptom: Coffee tastes bitter.
Cause: Water too hot. Over extracted.
Symptom: Coffee tastes burnt.
Cause: Group head dirty/handle dirty.
Remedy: Replace shower screen and shampoo filter basket & holder.
Symptom: Water runs over top of handle.
Cause: Head seal damaged.
Remedy: Replace head seal.
Symptom: Slow water flow from group.
Cause: Shower screen clogged
Remedy: Replace shower screen.
Symptom: Water under machine.
Cause: Drip tray full. Something else?
Remedy: Empty drip tray or call technician.
Symptom: No steam from wand.
Cause: Nozzle blocked.
Remedy: Remove nozzle and clear holes.
Symptom: Excessive water in grounds.
Cause: Filter basket not full. Coffee ground too fine.
Remedy: Fill filter basket completely. Coarsen grind.
Symptom: Pump lacks pressure.
Cause: Poor water supply. Pump defective.
Remedy: Call technician.