General Specifications
Diode Test Test current: 0.3mA max., Open circuit voltage: 1.5V DC typ.
Continuity Check Audible signal will sound if the resistance is less than 35
Temperature Sensor Requires Type-K thermocouple
Input Impedance 10MΩ (VDC & VAC)
AC Bandwidth 50 / 60Hz
Display 4000 count (0 to 3999 digits) LCD
Overrange indication For all functions “OL” is displayed (Note: For ACV measurements only, an
audible beep will also sound)
Auto Power Off After 15 minutes (approximately) of inactivity
Polarity No indication for positive; Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Low Battery Indication is displayed if battery voltage is critically low
Battery Two (2) 1.5V ‘AAA’ batteries
Fuses mA, µA ranges: 500mA/600V fast blow;
’A’ range: 10A/600V fast blow
Operating Temperature 32ºF to 122ºF (0ºC to 50ºC)
Storage Temperature -4
o
F to 140
o
F (-20
o
C to 60
o
C)
Operating Humidity <70% RH
Storage Humidity <80% RH
Operating Altitude 7000 ft. (2000 m) maximum.
Weight 9.17 oz (260 g) (includes holster).
Size 5.8” x 2.9” x 1.6 in. (147 x 76 x 42 mm) (includes holster)
Approvals CE
Safety This meter is intended for indoor use and protected, against the users, by
double insulation per EN61010-1 and IEC61010-1 3
rd
Edition (2010) to CAT
III 600V; Pollution Degree 2.
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which
measures are taken to limit the transient overvoltages to an appropriate low level. Note Examples
include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from
the fixed installation.
Note Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
Note Examples include switches in the fixed installation and some equipment for industrial use
with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.
Note Examples include electricity meters and primary over-current protection equipment
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Other manuals for Extech Instruments EX330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments EX330 and is the answer not in the manual?

Extech Instruments EX330 Specifications

General IconGeneral
BrandExtech Instruments
ModelEX330
CategoryMultimeter
LanguageEnglish

Related product manuals