EX330-EU-ENG – V4.2 1/08
17
Specifications
Function Range Resolution Accuracy
Non-contact
AC Voltage
detector
100 to
600VAC
Resolution & accuracy do not apply since the
meter does not display the voltage in this mode.
The lamp at the top of the meter’s display flashes
when voltage is sensed.
DC Voltage
(V DC)
400mV 0.1mV
±(0.5% reading + 2 digits)
4V 0.001V
±(1.0% reading + 2 digits)
40V 0.01V
400V 0.1V
600V 1V
±(1.5% reading + 2 digits)
AC Voltage
(V AC)
(50 / 60Hz)
400mV 0.1mV
±(1.0% reading + 30 digits)
4V 0.001mV
±(1.5% reading + 3 digits)
40V 0.01V
400V 0.1V
600V 1V
±(2.0% reading + 4 digits
DC Current
(A DC)
400μA 0.1μA ±(1.0% reading + 3 digits)
4000μA 1μA
±(1.5% reading + 3 digits)
40mA 0.01mA
400mA 0.1mA
10A 0.01A
±(2.5% reading + 5 digits)
AC Current
(A AC)
(50 / 60Hz)
400μA 0.1μA ±(1.5% reading + 5 digits)
4000μA 1μA
±(1.8% reading + 5 digits)
40mA 0.01mA
400mA 0.1mA
10A 0.01A
±(3.0% reading + 7 digits)