46
Summary table
Display D1
Display D2
Function
06:00 B
Start day phase/end night phase
22:00 C
Start night phase/end day phase
25°C D
Day phase max. temperature
20°C E
Night phase max. temperature
Once this function is active, it is still necessary to light the stove using button 1. When the stove
switches off because the maximum temperature has been reached, the message doffappears
on D1.The stove will switch on again automatically when the room temperature is 3°C lower than
the maximum temperature set.
e.g. Status of the stove – doff
Max. temperature set – 25°C
When the room temperature goes below 22°C (25 3 = 22°C), the stove will automatically start
again.
N.B.: This only occurs if the stove is in “doff” status, not in “off” status.
Manual controls via the front panel or remote control take precedence over any programmed
settings.
15.3 Pellet feed adjustment
Problems related to the quantity of pellets fall into one of two categories:
1 - LACK OF PELLETS
The stove cannot develop a suitable flame, tending to burn very poorly even at high
speeds.
At the lowest speed, the stove tends to almost burn out, causing the stove to go into NO
PELL” alarm status.
When “NO PELL” is displayed, there may still be some unburned pellets in the burn pot.
2 - EXCESS PELLETS
The stove develops a very high flame even at low speeds.
The flame tends to soil the stove window, darkening it almost completely.
The burn pot tends to get incrusted, blocking the air intake holes, due to the excessive
pellet load that is only partially burned.
N.B.: If this problem occurs just a few months after installation, check to make sure that the user
is correctly carrying out the regular cleaning schedule described in the instruction manual.
The adjustment is made on a percentage basis, and therefore any change of this parameter leads
to a proportional variation on all loading speeds of the stove.
To access the percentage adjustment of pellet feeding, you have enter the user programming by
pressing button 3, and while keeping it pressed, press button 5.
At this point use button 5 to move through the menu until you see “F” blinking on D2.

Table of Contents

Other manuals for Extraflame DIVINA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extraflame DIVINA and is the answer not in the manual?

Extraflame DIVINA Specifications

General IconGeneral
BrandExtraflame
ModelDIVINA
CategoryStove
LanguageEnglish

Related product manuals