Regulatory Information
AP-8533 Access Point Installation Guide 37
US and Canada
Co-located statement
To comply with FCC RF exposure compliance requirements, the antenna used for this
transmitter must not be co-located or operating in conjunction with any other transmitter/
antenna except those already approved in this filling.
To satisfy US and Canadian RF exposure requirements, a transmitting device must operate
with a minimum separation distance of 40 cm or more from a person's body.
Pour satisfaire aux exigences Américaines et Canadiennes d'exposition aux radiofréquences,
un dispositif de transmission doit fonctionner avec une distance de séparation minimale de
40 cm ou plus de corps d'une personne.
Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 40
cm between the radiator and your body.
NOTE IMPORTANTE: (Pour l'utilisation de dispositifs mobiles)
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour
un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un
minimum de 40 cm de distance entre la source de rayonnement et votre corps.
Remote and Standalone Antenna Configurations
To comply with FCC RF exposure requirements, Antennas that are mounted externally must
be professionally installed at a fixed location and operate with a minimum distance of 40
cm from all persons.
To comply with FCC Antenna requirements, the Antenna must be adjusted such that the RF
emission lobes are below 30 degrees elevation.
Power Supply
This device must be powered from a 802.3af or 802.3at compliant power source which has
been certified by the appropriate agencies, or by an Extreme approved UL LISTED ITE (IEC/
EN 60950-1, LPS/SELV) power supply with electrical ratings: Output 48 Vdc, min 0.75 A or
55 Vdc min 0.6 A, with a recommended ambient temperature greater than X degrees C.
Use of alternative power supply will invalidate any approvals given to this unit and may be
dangerous.