Power Options
Table 242: X695 Power Options
X695-48Y-8C 750 W AC power supply:
Part # XN-ACPWR-750W-F (front-to-back)
Part # XN-ACPWR-750W-R (back-to-front)
AC Input: 100-120/200-240 VAC, 50/60 Hz
3.5/1.8 A max. for each PSU
PSU Input Socket: IEC 320 C14
Power cord input plug: IEC 320 C13
750 W DC power supply:
Part # XN-DCPWR-750W-F (front-to-back)
Part # XN-DCPWR-750W-R (back-to-front)
DC Input: -54 VDC, 7.0 A max. for each PSU
Power Consumption
Table 243: X695 Power Consumption
Switch Model Minimum Heat
Dissipation
(BTU/hr)
Minimum Power
Consumption
(W)
Maximum Heat
Dissipation
(BTU/hr)
Maximum Power
Consumption
(W)
X695-48Y-8C 553 167 1600 469
Mean Time Between Failures (MTBF)
Table 244: X695-48Y-8C MTBF
Switch Mean Time Between Failures
X695-48Y-8C-AC-F 389719 hrs @ 25°C
X695-48Y-8C-AC-R 450269 hrs @ 25°C
CPU, Memory
Table 245: CPU, Memory
2.2 GHz 64-bit CPU
16 Gb memory, 128 Gb SSD
4GB eMMC Flash Memory
32 MB buer, per chip