dot1x max-reauth-req 1-255
Parameters
Name Description
<1-255>
number of times
dot1x re-authentication
Description
re-authentication
Syntax
dot1x re-authentication
Parameters
None.
dot1x system-auth-controln
Description
System authentication control
Syntax
dot1x system-auth-control
Parameters
None.
dot1x timeout
Description
Timeout control
Syntax
dot1x timeout {quiet-period v_10_to_1000000} | {tx-period v_1_to_65535}
Parameters
Name
Description
quiet-period
Time in seconds before a MAC-address that failed authentication gets a new
authentication chance
tx-period
the time between EAPOL retransmissions
ISW Commands