Parameters
Name Description
alarm
Configure an RMON alarm
event
Configure an RMON event
rmon alarm
Description
RMON Alarm
Syntax
rmon alarm id oid_str interval {absolute | delta} rising-threshold
rising_threshold [rising_event_id] falling-threshold falling_threshold
[falling_event_id] {[rising | falling | both ] }
Parameters
Name Description
id Alarm entry ID
interval Sample interval
absolute Test each sample directly
delta Test delta between samples
rising_threshold <-2147483648-2147483647> rising threshold value
rising_event_id <0-65535> Event to fire on rising threshold crossing
falling_threshold <-2147483648-2147483647> falling threshold value
falling_event_id <0-65535> Event to fire on falling threshold crossing
rising Trigger alarm when the first value is larger than the rising threshold
falling rigger alarm when the first value is less than the falling threshold
both
Trigger alarm when the first value is larger than the rising threshold or less than the
falling threshold (default)
rmon event
Description
RMON Event
Syntax
rmon event id [log] [trap community] {[description description]}
Parameters
ISW Commands
ISW Series Managed Industrial Ethernet Switch Command Reference Guide 71