Sets LLDP TX interval (the time between each LLDP frame transmitted in seconds).
Syntax
lldp timer 5-32768
Parameters
Name Description
5-32768
5-32768 seconds.
lldp tlv-select
Description
Which optional TLVs to transmit.
Syntax
lldp tlv-select {management-address | port-description | system-
capabilities | system-description | system-name}
Parameters
Name
Description
management-address
Enable/Disable transmission of management address
port-description
Enable/Disable transmission of port description
system-capabilities
Enable/Disable transmission of system capabilities
system-description
Enable/Disable transmission of system description
system-name
Enable/Disable transmission of system name.
lldp transmission-delay
Description
Sets LLDP transmision-delay. LLDP transmission delay (the amount of time that the transmission of
LLDP frames will delayed after LLDP configuration has changed) in seconds.)
Syntax
lldp transmission-delay 1-8192
Parameters
Name
Description
1-8192
transmission-delay seconds
ISW Commands