EasyManua.ls Logo

F'real FRLB4 - Consumer Error Messages: Product and System; Product Temperature and Motor Cool Down Errors; Water and Unexpected Error Messages

F'real FRLB4
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
“OOPS! Wrong cup size used.
TRIGGER: If the cup Size sensors are triggered too early, too late or not at all
1. Ensure the customer is using a f’real cup.
2. Locate the Cup Sensors and clean them using a damp paper towel. Run another cycle. If the error persists, proceed Step 3.
3. Remove throat panel from the boom of the blending chamber. Check panel for debris. Ensure the cup sensor holes are not
obstructed in any way. Clean as needed. If damaged, replace Cup Size Sensors (Parts Manual: Cup Sensors).
4. Check the wiring for the Cup Size Sensors. Ensure the wires are not pinched or damaged. If the wires are damaged, replace
Cup IR Sensors Wiring Harness (Parts Manual: Glossary).
5. If error persists, replace Low Voltage Control Board (Parts Manual: Control Boards, Lower).
“HEY! The product is not cold enough to be blended.
TRIGGER: During the rst part of the rst bore, if the cup carriage moves fast and/or the mix motor current load is too small, it
assumes there is no product in the cup or it has already been blended
1. Ensure the display freezer is between 0-6°F.
A. Perform the Squeeze Test. Using a chocolate milkshake, squeeze the middle of the cup. You should be able to squeeze a
dime-size dent in the milkshake.
B. Ensure the product is tempered (see the “Too Thick/Too Thin Shakes” secon).
2. Ensure f’real product cups are not over-lled. A properly lled cup, before blending, will be 2/3 full. If cups are over-lled or if
they are thawed and re-frozen upside down or at an angle, those shakes will not blend. Try blending a properly lled cup.
3. Verify that the Blending Components are secure and assembled correctly. If damaged, replace Blending Assembly (Parts
Manual: Mixing System).
“WE’RE SO SORRY! The blender needs to take a break to let the motor cool down.
TRIGGER: Mix Motor temperature exceeds threshold of 180°F
1. Allow one hour for the Mix Motor to cool down. This is caused by several shakes being blended one aer the other.
2. Ensure the display freezer is between 0-6°F.
A. Perform the Squeeze Test. Using a chocolate milkshake, squeeze the middle of the cup. You should be able to squeeze a
dime-size dent in the milkshake.
B. Ensure the product is tempered (see the “Too Thick/Too Thin Shakes” secon).
3. Spin Mix Motor Spindle by hand to ensure it spins freely. If the spindle won’t turn or is dicult to turn, replace Mix Motor
(Parts Manual: Mixer System).
“WE’RE SO SORRY! The blender needs water to blend!”
TRIGGER: Lower scour minimum ow limit of 60mL was not reached within 2.5 seconds
1. If the blender is unable to achieve 60mL of water within 2.5 seconds, the front screen will read:
A. "We're So Sorry! The blender needs water to blend! Store Associate: The water connecon might be turned o or may
need beer water pressure. To re-test water connecon, press the “Regular” and “More Thick” buons for 7 seconds.
2. If the blender sits in the above state without being reset, it will reset automacally and re-try to complete the Scour rinse
event every 5 minutes for 30 minutes, total. Aer it reaches its nal try and sll can't get the 60mL within 2.5 seconds, Error 7D
will present on the screen. See “Error 7D” troubleshoong.
“WE’RE SO SORRY! The blender experienced unexpected Error Code C11.
TRIGGER: The Cup in Place sensor is triggered for 60 seconds aer a shake blend process is complete.
1. Clean both cup sensors using a dampened “Q-p,” coon swab or paper towel.
2. Access the LVCB Status Window and locate Line R: “CupInP: 1/0”
A. If the value is: "CupInP : 0" - troubleshoong is complete.
B. If the value is: "CupInP : 1" - Proceed to step 3.
3. Remove the Le-Tail, Right-Tail and Throat Panel from the boom of the blending chamber.
A. Check panel for debris.
B. Ensure the cup sensor holes are not obstructed in any way.
C. Clean as needed.
D. Replace if damaged.
4. Remove the Le Side Panel and locate the wiring harness behind the Blending Chamber.
A. Inspect the wiring for any damage.
B. Unplug and Re-plug the wires back into place.
5. Turn the blender around to locate the Venlaon Grate at the base. Ensure that is completely clean and clear.
A. If sll an issue, replace the Cup In Place Sensor Set (Parts Manual: Cup Sensors).