8. FUNCTION LOGICS
Status
Open
(pulse)
Close
(maintained)
Stop Safe
Closed Opens /
Disables
Open and Close
/
Opening / Closes Locks /
Open / Closes
Disables
Open and Close
Disables
closing
Closing Opens Closes Locks Opens
Locked Opens Closes
Disables
Open and Close
Disables
closing
Status
Open
(pulse)
Close
(pulse)
Stop Safe
Closed Opens /
Disables
Open and Close
/
Opening / Closes Locks /
Open / Closes
Disables
Open and Close
Disables
closing
Closing Opens / Locks Opens
Locked Opens Closes
Disables
Open and Close
Disables
closing
Status
Open
(held)
Close
(held)
Stop Safe
Closed Opens /
Disables
Open and Close
/
Opening Opens Locks Locks /
Open / Closes
Disables
Open and Close
Disables
closing
Closing Opens Closes Locks Locks
Locked Opens Closes
Disables
Open and Close
Disables
closing
Status
Open
(pulse)
Close
(pulse)
Stop Safe
Closed Opens /
Disables
Open and Close
/
Opening Locks Closes Locks /
Open Closes Closes
Disables
Open and Close
Disables
closing
Closing Locks / Locks Opens
Locked
Starts in opposite
direction (always
closes after a Stop)
Closes
Disables
Open and Close
Disables
closing
Status
Open
(pulse)
Close
(pulse)
Stop Safe
Closed
Opens and closes
after pause time
/
Disables
Open and Close
/
Opening Locks Closes Locks /
Pause Locks Closes Locks
Repeats
pause
Closing Opens / Locks Opens
Locked Closes Closes
Disables
Open and Close
Disables
closing
Status
Open
(pulse)
Close
(pulse)
Stop Safe
Closed Opens /
Disables
Open and Close
/
Opening /
Completes opening
and then closes
Locks /
Open / Closes
Disables
Open and Close
Disables
closing
Closing Opens / Locks
Locks and clo-
ses on release
Locked Opens Closes
Disables
Open and Close
Disables
closing
Status
Open
(pulse)
Close
(pulse)
Stop Safe
Closed
Opens and closes
after pause time
/
Disables
Open and Close
/
Opening /
Completes
opening and
then closes
Locks
/
Pause
Recharges
pause time
Closes Locks
Recharges
pause time
Closing Opens / Locks Opens
Locked Opens Closes
Disables Open
and Close
Disables
Close
LOGIC B/C
LOGIC B
LOGIC C
LOGIC EP
LOGIC AP
LOGIC P
LOGIC A
EC DECLARATION OF CONFORMITY
Manufacturer : FAAC S.p.A.
Address: Via Benini, 1 - 40069 Zola Predosa BOLOGNA - ITALY
Declares that: 596/615BPR control board,
• conforms to the essential safety requirements of the following
directives:
73/23/EEC and subsequent amendment 93/68/EEC.
89/336/EEC and subsequent amendment 92/31/EEC and 93/68/
EEC
Additional note:
This product underwent tests in a typical uniform configuration (all
products manufactured by FAAC S.p.A.).
Bologna, 01 January 2006
The Managing Director
A. Bassi