E1 Logic: How the gate leaf behaves
Leaf Signal
status
Open or A/C
1
Stop Reversing
Closed Opens no effect no effect
Open Closes no effect no effect
Closing Opens Stops Opens
Opening Stops Stops no effect
Stopped
Closes
2
no effect no effect
1
An A/C signal causes the leaf to partially open.
2
The leaf opens if reversing devices are triggered.
E2 Logic: How the gate leaf behaves
Leaf Signal
status
Open or A/C
1
Stop Reversing
Closed Opens no effect no effect
Open Closes no effect no effect
Closing Opens Stops Stops. Opens
when reversing
device no
longer triggered
Opening Stops Stops no effect
Stopped
Closes
2
no effect no effect
1
An A/C signal causes the leaf to partially open.
2
Leaf opens if reversing devices are triggered.
A1 Logic: How the gate leaf behaves
Leaf Signal
status
Open or A/C
1
Stop Reversing
Closed Opens, pauses,
and closes
no effect no effect
Open Resets pause
count, pauses,
and closes
Stops
pause
count
Freezes the
pause count until
reversing device
no longer
triggered
Closing Opens Stops Opens
Opening no effect Stops no effect
Stopped Closes no effect no effect
1
An A/C signal causes the leaf to partially open.
A2 Logic: How the gate leaf behaves
Leaf Signal
status
Open or A/C
1
Stop Reversing
Closed Opens, pauses,
and closes
no effect no effect
Open Closes Stops
pause
count
Closes after 5 sec
when reversing
device no longer
triggered
Closing Opens Stops Stops. Opens
when reversing
device no longer
triggered
Opening no effect Stops no effect
Stopped Closes no effect no effect
1
An A/C signal causes the leaf to partially open.
S1 Logic: How the gate leaf behaves
Leaf Signal
status
Open or A/C
1
Stop Reversing
Closed Opens, pauses,
and closes
no effect no effect
Open Closes Stops
pause
count
Closes after 5 sec
when reversing
device no longer
triggered
Closing Opens Stops Stops. Opens
when reversing
device no longer
triggered
Opening Closes Stops no effect
Stopped Closes no effect no effect
1
An A/C signal causes partial opening.
S2 Logic: How the gate leaf behaves
Leaf Signal
status
Open or A/C
1
Stop Reversing
Closed Opens, pauses,
and closes
no effect no effect
Open Closes Stops
pause
count
Freezes the
pause count until
reversing device
is no longer
triggered
Closing Opens Stops Stops. Opens
when reversing
device no longer
triggered
Opening Closes Stops no effect
Stopped Closes no effect no effect
1
An A/C signal causes partial opening.
B Logic: How the gate leaf behaves
Leaf Signal
status Open
A/C
1
Stop Reversing
Closed Opens no effect no effect no effect
Open no effect Closes no effect no effect
Closing no effect no effect Stops Stops
Opening no effect no effect Stops no effect
Stopped Opens Closes no effect no effect
1
An A/C signal functions as a close signal in B logic.
C Logic
1
: How the gate leaf behaves
Leaf Signal
status Open
A/C
2
Stop Reversing
Closed Opens no effect no effect no effect
Open no effect Closes no effect no effect
Closing no effect Closes Stops Stops
Opening Opens no effect Stops no effect
Stopped Opens Closes no effect no effect
1
The leaf moves only while a switch button is pressed.
2
An A/C signal functions as a close signal in C logic.