29
ENGLISH
FUNCT.NO.
LEDS FUNCTIONS LED 6
12345
0 OFF OFF OFF OFF OFF Output Level III OFF
1 ON OFF OFF OFF OFF One-way with lock active OFF
One-way with lock inactive ON
2 OFF ON OFF OFF OFF NIGHT function (terminal 3-960MP) OFF
ONE-WAY function (terminal ON
3-960MP)
3 ON ON OFF OFF OFF Gong output (terminal 24-960MP) OFF
Interlock output (terminal 24-960MP) ON
4 OFF OFF ON OFF OFF SLAVE (interlock) OFF
MASTER (interlock) ON
5 ON OFF ON OFF OFF Emergency closing (terminal OFF
11-960MP)
Emergency opening (terminal ON
11-960MP)
6 OFF ON ON OFF OFF Emergency command - N.C. OFF
contact (terminal 11-960MP)
Emergency command - N.O. ON
contact (terminal 11-960MP)
7 ON ON ON OFF OFF CODIS - temporary connection OFF
CODIS - permanent installation ON
8 OFF OFF OFF ON OFF 15 kg static force OFF
9 kg static force ON
9 ON OFF OFF ON OFF CODIS inhibited inactive OFF
CODIS inhibited active ON
10 OFF ON OFF ON OFF Standard opening pause time OFF
Immediate closing ON
11 ON ON OFF ON OFF Door open/closed indication - N.O. OFF
contact (terminals 18/19-960MP)
Door open/closed indication - N.C. ON
contact (terminals 18/19-960MP)
12 OFF OFF ON ON OFF Alarm warning - N.O. OFF
contact (terminal 21-960MP)
Alarm warning - N.C. ON
contact (terminal 21-960MP)
13 ON OFF ON ON OFF “Double swing door” output inactive OFF
“Double swing door” output ON
active (terminal 23-960MP)
14 OFF ON ON ON OFF SLAVE (double swing door) OFF
MASTER (double swing door) ON
15 ON ON ON ON OFF Restore STANDARD settings OFF
Retain programmed settings ON
16 OFF OFF OFF OFF ON Opening commands stored OFF
(interlock)
Opening commands not stored ON
(interlock)
17 ON OFF OFF OFF ON TEST programme inactive OFF
TEST programme active ON
18 OFF ON OFF OFF ON Level II RESET active OFF
Level II RESET inactive ON
19 ON ON OFF OFF ON STANDARD internal command OFF
(terminal 9-960MP)
STEP-BY-STEP internal command ON
(terminal 9-960MP)
When the “-” pushbutton is pressed, the door speed,
opening excursion and pause time are decreased.
4) Return to Level I (operating functions) by pressing the “+”
and “-” pushbuttons simultaneously.
Notes: - The CODIS automatically returns to Level I after 2
minutes of inactivity.
- To prevent the settings from returning to standard
values after a RESET or a voltage drop, “protect” the
programmed values by activating function 18 at
Level III (see paragraph 8.3).
8.3. LEVEL: III - PROGRAMMING FUNCTIONS
The CODIS has a programming level where certain functions
can be selected.
These functions are required for several special applications.
Note: a voltage drop or a RESET command will not cancel the
programming on Level III.
Standard programming can be restored by means of function
15 (see Table 7).
To access Level III, proceed as follows:
1) Select the NIGHT operating function by causing LED 1 to
light up. Press the “+” pushbutton to move the lighting of
the LEDs one position up. Press the “-” pushbutton to move
the lighting of the LEDs one position down.
2) Press the “+” and “-” pushbuttons simultaneously for about
2 seconds, until the red ERROR LED lights up.
3) Enter the access code by pressing the “+” and “-”
pushbuttons in the following sequence: “+ + + - - + + +”.
Note: after the lighting up of the red ERROR LED, if the code is
not entered within 10 seconds the CODIS will automatically
return to Level I.
4) .Select the function to be programmed by pressing the “+”
or “-” pushbutton so as to obtain the combination of lit LEDs
indicated in Table 7.
5) Press the “+” and “-” pushbuttons simultaneously to activate
or deactivate the function, and check the status of LED 6,
according to the indications of Table 7.
Note: the standard programming is the one with LED 6 unlit
(OFF).
6) To return to Level I (operating functions), repeatedly press
the “-” pushbutton until all the six LEDs are off, then press
the “+” and “-” pushbuttons simultaneously.
Note: the CODIS will automatically return to Level I after 2
minutes of inactivity.
8.3.1. AVAILABLE FUNCTIONS
function 1
One-way with lock activated: in the ONE-WAY operating
function, the closed door is locked by the electric lock.
One-way with lock deactivated: in the ONE-WAY operating
function, the closed door is not locked by the electric lock.
function 2
NIGHT function: the activation of the input between terminals
2 and 3 (960MP) selects the NIGHT operating function, with
priority over the function selected on the CODIS.
ONE-WAY function: the activation of the input between
terminals 2 and 3 (960MP) selects the ONE-WAY operating
function, with priority over the function selected on the CODIS.
The control panel will show which function has been selected,
by means of the lighting up of LED 1 or 2.
When the input is deactivated, the operating function
previously selected on the CODIS returns automatically.
function 3
Gong output: the operation of the closing safety device
activates the 24 Vdc output between terminals 14 and 24
(960MP) for 1 second, at intervals of 0.5 seconds.
Table 7: programming functions