9
DS 1 SETTINGS
SW 4 to SW 12
OPENING DELAY SW 4
The opening of leaf 2 is delayed after the opening of leaf 1. This is
to avoid that the gate’s leafs interfere with each other during the
initial part of the movement.
0 sec (default) OFF
2 sec ON
REVERSE AND LAST STROKE SW 5
If active, before opening, while the gate is closed, the motors thrust
to close for 2 s to facilitate the release of the electric lock. At closing
the motors are activated for a nal stroke after slowdown to facilitate
locking of the electric lock.
inactive (default) OFF
active ON
MAX THRUST AT STARTUP SW 6
With this fuction active the motors work at maximum force at star-
tup (regardless of the force setting) during the initial phase of the
movement. Useful for heavy leafs
inactive (default) OFF
active for 3 sec ON
AUTOMATIC OPENING IN CASE OF
POWER FAILURE
SW 7
If active and with the optional backup battery installed, the board
will open the gate after one minute from the power failure.
Within the minute wait it’s always possible to open and close the
gate with a command. If the logic used has a pause time the board
will close the gate when the power comes back.
inactive (default) OFF
active ON
CLOSING SAFETY LOGIC SW 8
With this function you can choose the behaviour of the closing safety.
With SW8 OFF the gate movement will be inverted as soon as the safety
is active, with SW8 ON the gate will stop shen the safety is active and
will reverse only when the safety is deactivated again.
immediate inversion (default) OFF
inversion when cleared ON
PREFLASHING SW 9
This function activates the ashing lamp for 5s before the move-
ment of the gate
inactive (default) OFF
active for 5 sec ON
EXTRA SENSITIVITY TO OBSTACLE
DETECTION
SW 10
If active this function allows to have an immediate reverse in case the
gate hits a rigid obstacle, while keeping the motor active in case of a
gradual increment of resistance, like with wind pressure on the gate
or increased friction
inactive (default) OFF
active ON
OUT FUNCTION (pin 9)
max 100mA
SW 11 SW 12 ACTIVATES AN OUTPUT TO GND (-) DEPENDING ON
THE SETTING OF DIP SWITCHES 11-12
FAIL SAFE active
USE OUT (pin 9) AS NEGATIVE FOR
PHOTOCELLS
ON ON
This setting enables a self test of the photocells befor
moving the gate. If the test fails thegate will not move.
Pin 9 must be used as the negative power supply of the
photocells transmitters.
OBSTACLE ALARM OFF OFF
After the second consecutive obstacle detection all the commands
are disabled and the pin 9 output is activated. To re-enable the op-
erator you need to cycle power and open the STOP contact (pin 3)
OUTPUT ALWAYS ACTIVE, EXCEPT
DURING THE FIRST 3 SEC AFTER THE
START OF ANY MOVEMENT (OPEN /
CLOSE)
OFF ON
Use pin 9 as power supply negative for any accessory that must be
have the power shut down for 3 sec after every movment (open
or close) for example a Maglock
LAMP FUNCTION ON OFF
Use pin 9 as power supply negative for a warning lamp.
The lamp will be active during opening, pause and
stop. Flashing during close, o when the gate is closed
5.3 DIP SWITCH DS1 SW4...........SW12: BOARD SETUP