Key Components of E124 Board
Description of Key Components
LCD SIGNALS AND PROGRAMMING DISPLAY DL8 “FCA2” STATUS LED -LIMIT SWITCH OPEN – IF GATE CLOSED ON
SW4 “+” PROGRAMMING BUTTON DL9 “FCC2” STATUS LED -LIMIT SWITCH CLOSED – IF GATE CLOSED OFF
SW5 “-” PROGRAMMING BUTTON DL12 LED FOR BUS-2EASY DEVICE ACTIVE
SW6 “F” PROGRAMMING BUTTON DL13 LED FOR BUS-2EASY DIAGNOSTICS
SW7 “RESET SW” SOFTWARE RESET BUTTON DL14 LED SIGNALING PRIMARY POWER ON
DL1 “IN1” STATUS LED – DEFAULT OPEN A - NORMAL STATE OFF DL19 LED FOR WHEN “SW7” IS PRESSED
DL2 “IN2” STATUS LED – DEFAULT OPEN B - NORMAL STATE OFF DL20 LED SIGNALLING “ALARM”
DL3 “IN3” STATUS LED – DEFAULT STOP - NORMAL STATE ON J3 CONNECTOR FOR CONNECTION OF BUS-2EASY DEVICES
DL4 “IN4” STATUS LED – DEFAULT FSW OP - NORMAL STATE ON J4 CONNECTOR FOR TERMINAL BOARD INPUTS
DL5 “IN5” STATUS LED – DEFAULT FSW CL - NORMAL STATE ON J5 CONNECTOR FOR OUTPUT 2 (OUT2)
DL6 “FCA1” STATUS LED -LIMIT SWITCH OPEN – IF GATE CLOSED ON J6 CONNECTOR FOR TRAVEL LIMITS
DL7 “FCC2” STATUS LED -LIMIT SWITCH CLOSED – IF GATE CLOSED OFF
Electrical Connections
Connection of Traditional Photocells
The E124 Control Board allows for the use of traditional photocells (n/c with relay). Below is a layout drawing showing the
basic positions normally covered. The wiring diagram is for Fail-Safe enabled photocells. In order to comply with the standards,
all devices used for safety should either have a circuit monitored by the control board or be self-monitoring. FAAC Control
boards are able to perform the monitoring by the use of a Fail-Safe function, whereby the test negative is momentarily dropped
(please note that this may not be compatible with non-FAAC equipment). This function is enabled by entering Advanced
Programming (detailed below) and setting function o1 to 01.