Page | 4
Connection of FAAC BUS 2Easy Photocells
Connection of FAAC BUS 2easy Safecoders and S800 Encoders
The E124 Control Board also allows for the use of FAAC BUS 2easy photocells which allow for simpler cabling, a reduced power
consumption, and Failsafe checking of each device independently. The Failsafe checking being performed by our proprietary
FAAC BUS 2easy communication protocol also assist the installer by removing the need for separate cabling for a monitoring
circuit. (Please note that FAAC BUS photocells are only compatible with FAAC Control Boards and those using the BUS Terminal
or using the BUS Relay Interface Board).
J3
The E124 Control Board also allows for the use of FAAC BUS 2easy Safecoders and the S800/S450 Encoders (required for
operation these operators). This allows for the control board to have positional accuracy and allows for the possibility of
inherent obstacle detection (Force Testing with the use a calibrated instrument to BS EN 12445/12453 norms (such as the
Microtronics Blueforce Tester, available from FAAC UK) will be required to confirm suitability but please note that additional
devices maybe required such as Safety Edges).