E721 18 532014 - Rev.E
ENGLISH
LOGIC "A" PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and recloses after
the pause time
opens the gate partially
and closes it after pause
time B
no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING no effect (1) no effect recloses the gate locks operation see 2nd level prog. no effect
locks and opens on
disengagement
(stores CLOSE)
OPEN IN PAUSE reloads pause time (1) reloads pause time B recloses the gate locks operation no effect
reloads pause time
(CLOSE inhibited)
reloads pause time
(CLOSE inhibited)
DURING CLOSING reopens the gate reopens the gate no effect locks operation no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement
(stores CLOSE)
LOCKED closes the gate closes the gate closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
LOGIC "EP" PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the gate opens the gate partially no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING locks operation (1) locks operation recloses the gate locks operation see 2nd level prog. no effect
locks and opens on
disengagement (OPEN
locks - stores CLOSE)
OPEN recloses the gate (1) recloses the gate recloses the gate
no effect
(OPEN/CLOSE inhibited)
no effect
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
DURING CLOSING locks operation locks operation no effect locks operation no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement (OPEN
locks - stores CLOSE)
LOCKED
resumes motion in reverse
direction. After STOP, always
closes
resumes motion in reverse
direction. After STOP, always
closes
closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect (OPEN locks
- stores CLOSE)
LOGIC "E" PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the gate opens the gate partially no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING locks operation (1) locks operation recloses the gate locks operation see 2nd level prog. no effect
locks and opens on
disengagement (OPEN
locks - stores CLOSE)
OPEN recloses the gate (1) recloses the gate recloses the gate
no effect
(OPEN/CLOSE inhibited)
no effect
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
DURING CLOSING reopens the gate reopens the gate no effect locks operation no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement (OPEN
locks - stores CLOSE)
LOCKED closes the gate closes the gate closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect (OPEN locks
- stores CLOSE)
(1) During the partial opening cycle, an OPEN A pulse causes total opening
LOGIC "A1" PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and recloses after
the pause time
opens the gate partially
and closes it after pause
time B
no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING no effect (1) no effect recloses the gate locks operation see 2nd level prog.
continues to open and
recloses immediately
locks and opens on
disengagement
(stores CLOSE)
OPEN IN PAUSE reloads pause time (1) reloads pause time B recloses the gate locks operation no effect
locks and immediately
closes on disengagement
reloads pause time
(CLOSE inhibited)
DURING CLOSING reopens the gate reopens the gate no effect locks operation no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement
(stores CLOSE)
LOCKED closes the gate closes the gate closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
10 FUNCTION LOGICS
In brackets, the effects on the other inputs when
the pulse is active.
The CLOSE command can be enabled on the OPEN
B input from programming level 2.
If enabled during leaf motion, the SAFE command
will immediately and completely reverse it; when
the automated system is stopped, if kept enabled
it will prevent its movement.