Translation of the original instructions
ENGLISH
5.3 CONNECTING MULTIPLE BOLLARDS
Up to 3 bollards can be connected simultaneously to a single JE275
board. To connect them, follow the diagrams below.
UPPER limit switch
LOWER limit switch
5.2 BOARD PROGRAMMING
After connecting and switching on the power to the control board as
per the previous chapter, select the work pre-setting for the bollard
J275 2K HA by performing the following operation:
1. Access level 1 programming by holding down the F button on the
board (26). The letters
dF will appear on the display.
2. Release the F button and with the
+ button, select the value 05
3. Press the F button and hold it down whilst simultaneously pressing
the
-
button to exit programming screen and save the changes
made.
4. Press the F button and hold it down, as well as pressing + for
around 10 seconds, until the display shows
01
5. Release the buttons, then press the F button scroll until you reach
the
b6 parameter
6. Set the value
b6 = Y
!
Setting b6 = Y causes the bollard to raise immediately when the
emergency input is activated.
7. Press the F button and hold it down whilst simultaneously pressing
the
-
button to exit programming screen and save the changes
made.
L
For further information on programming the board, please refer to the
relevant instructions.