3
4
J275 2K HA 8 532208 - Rev.A
1240
1175
525
275
462
Translation of the original instructions
ENGLISH
OPTIONAL ACCESSORIES
Emergency lowering device
(solenoid valve)
Obstacle detection device
(pressure switch)
Cover
2 Technical data
Power supply voltage 230 V ~ 50 Hz
Max power 575 W
Max force 2500 N
Pump delivery 3 l/min
Lifting time ~ 8 s
Lowering time ~ 4.5 s
Ambient operating temperature -15 °C - +55 °C
Ambient operating temperature (with optional heater) -25 °C - +55 °C
Type of use Intensive
Bollard weight 160 kg
Pit weight 60 kg
Oil quantity 1.5 l
Oil type FAAC HP OIL
Protection rating IP56
Hydraulic control unit protection rating IP67
Dimensional drawing
See 4
Thrust capacitor (pre-wired) 16 µF - 400V
Impact resistance 85 kJ
Break-in resistance 287 kJ
Impact resistance (STAINLESS STEEL) 134 kJ
Break-in resistance (STAINLESS STEEL) 414 kJ
Break-in resistance (double configuration) 656kJ (M30)
Continuous use time (ROT) 110 min at 23°C
Load class (EN124) C250 (25 t)
3.8 DIMENSIONAL DRAWING