J275 2K HA 22 532208 - Rev.A
24
45 Nm
24
2
1
S
1
2
3
4
5
2
S
252321 26242220
MOT1
COM
MOT2
COM
COM
LAMP
FAN
S
Translation of the original instructions
ENGLISH
7.2 INSTALLING THE SOLENOID VALVE
1. Remove the hydraulic unit following points 1 to 5 in the § "Remov-
ing the hydraulic unit” section.
2. Place the hydraulic unit in a horizontal position.
3. Remove the plug on the distribution flange.
4. Screw the solenoid valve onto the distribution flange.
5. Install the control coil onto the solenoid valve.
6. Remove the plug from the cable gland 41-1, insert the cable
and connect it to the connector 2 following the indications shown
in the diagram.
Yellow
Brown
Rapid lowering
Mains voltage
(230V)
Standard lowering
Red
Blue
CONNECTING THE CONTROL COIL
The solenoid valve allows the bollard to be lowered in the event of
a mains power failure. The bollard can be lowered more slowly or
more quickly depending on the type of connection. Follow the
connection diagrams below.