3
85
1060
50
75
100
Z
a° (3)
a° (2)
D
a° (1)
(3)
(2)
(1)
TAB. 1
B
75-84 85-94 95-104 105-114 115-124 125-134 135-144 145-154 155-164 165-175
D
20-24 110° (3) 110° (3) 115° (3) 108° (3) 100° (3) 100° (3)
25-34
108° (3) 110° (3) 110° (3) 103° (3) 100° (3) 94° (3)
35-44
100° (3) 107° (3) 108° (3) 104° (3) 111° (2) 104° (2) 100° (2)
45-54 100° (3) 105° (3) 106° (3) 100° (3) 106° (2) 100° (2) 96° (2)
55-64 97° (3) 100° (3) 105° (3) 99° (3) 107° (2) 100° (2) 96° (2) 92° (2)
65-74 93° (3) 97° (3) 100° (3) 100° (3) 110° (2) 101° (2) 96° (2) 102° (1) 98° (1)
75-84 90° (3) 95° (3) 100° (3) 105° (2) 102° (2) 111° (1) 105° (1) 98° (1) 94° (1)
85-94 90° (3) 90° (3) 95° (3) 100° (2) 104° (2) 96° (2) 104° (1) 100° (1) 94° (1) 90° (1)
95-104
90° (3) 90° (3) 95° (3) 100° (2) 96° (2) 106° (1) 98° (1) 96° (1) 90° (1)
105-114
90° (3) 90° (3) 95° (2) 97° (2) 103° (1) 99° (1) 94° (1) 92° (1)
115-124
90° (3) 90° (2) 95° (2) 98° (1) 100° (1) 94° (1)
125-134
90° (2) 90° (2) 95° (1) 98° (1) 94° (1)
135-144
90° (2) 90° (2) 95° (1) 94° (1)
145-154
90° (1) 90° (1) 94° (1)
155-164
90° (1) 90° (1)
165-170
90° (1)
TAB.1
B
XXX XXXX
D
XXX 120° (3) 120° (3)
XXX 110° (2) 110° (2)
XXX 115° (1) 110° (1)
a
B
ENGLISH
ATTENTION: do not cut for any reason the rear bracket
Make reference to figures 4 and 5 and to table 1 to determine the installation position of the operator.
INSTALLATION DIMENSION "B"
(SEE FIGURE 4-5)
INSTALLATION
DIMENSION
"D"
(SEE FIGURE 5)
- INTERSECT THE DIMENSIONS "D" AND "B" TO OBTAIN THE MAXIMUM VALUE OF OPENING GRADES.
- ATTENTION: USE MECHANICAL LIMIT SWITCHES IN ORDER NOT TO EXCEED THE MAXIMUM OPENING GRADES STATED IN TABLE 1 AND GUARANTEE
THE CORRECT OPERATION OF THE AUTOMATED SYSTEM.
HOLE TO BE USED
ON THE REAR
BRACKET
HOLE TO BE USED ON THE REAR BRACKET
Dimensions in millimeters
Fig. 4
Fig. 5
Dimensions in millimeters
3.2 INSTALLATION DIMENSIONS (Dimensions in millimeters)
If the gate structure does not allow the stable fixing of the front fitting, create a firm bearing surface in the leaf structure.
- It is advisable to grease all fixing pins - Opening and closing stops must always be installed - Play special attention not to
damage the operator rod
3.2.1 APPLICATION WITH BRACKET FASTENED TO THE COLUMN