EN 3
1 GENERAL INFORMATION
1.1 PURPOSE OF THE APPLIANCE
Gas hobs are equipped with an integrated control system and are designed to be fitted in a
kitchen worktop. They are designed for the preparation of meals only in a household. They must
not be used for other purposes!
1.2 TECHNICAL DATA
Table 1
Type
Characteristics
6CFI-
5GL BUT
6CFI-
5GLST
BUT
6CFI-
5GLST
NAT
6CFI-
4GLS
BUT
6CFI-
4GLS
NAT
6CFI-
4GLSB
NAT
6CFIE-
4GLS
NAT
width 700 700 700 594 594 594 594
depth 575 575 575 520 520 520 520
Hob's
overall
dimensions
[ mm ]
height 48 48 48 41 41 41 41
Supply voltage 1N ~ 230V 50Hz
small∅ 45 mm /1,0
kW
1 1 1 1 1 1 1
medium∅ 65 mm /
1,75 kW
2 2 2 2 2 2 2
large∅ 91 mm / 3,0
kW
1 1 1 1 1 1 1
Number
of
gasburne
rs [units]
triple crown burner
∅125 mm / 3,6 kW
1 1 1 — — — —
Knob-controlled spark ignitors
• • • • • • •
Flame failure device
—
• • • • • •
Hob surface
Glass
black
Glass
black
Glass
black
Glass
black
Glass
black
Glass
white
Glass
black
The hobs can be supplied with the following types of gas:
– natural gas 2H – (G20 20 mbar)
– LPG G30 29/37 mbar
Table 2
Type of gas Small burner Medium burner Large burner
Three crown
burner
2H–(G20 20 mbar)
X072 Z097 Y118 T135
LPG G30 29/37
mbar
050 065 085 095