Error solving manual.
CNC 8060
CNC 8065
·13·
(REF: 1709)
0092 'DRV variables having the same identifier (ID) cannot have different MODE or TYPE'
DETECTION During the validation of the machine parameters.
CAUSE There are drive variables (DRV) in the OEM machine parameters with the same
identifier (ID) and different access type (synchronous or asynchronous) or different
access mode (read or write).
SOLUTION DRV variables with the same identifier must have the same type of access (parameter
TYPE) and the same access mode (parameter MODE).
0093 'DRV variables having the same name (MNEMONIC) cannot have different ID, MODE or
TYPE'
DETECTION During the validation of the machine parameters.
CAUSE There are drive variables in the OEM machine parameters with the same mnemonic
and different Sercos identifier (ID), different access type (synchronous or
asynchronous) or different access mode (read or write).
SOLUTION The DRV variables with the same mnemonic must have the same Sercos identifier
(parameter ID), the same type of access (parameter TYPE) and the same access
mode (parameter MODE).
0094 'Some channel must have parameter HIDDENCH = No'
DETECTION During the validation of the machine parameters.
CAUSE All the channels of the system are defined as hidden.
SOLUTION The CNC does not allow all the channels of the system to be hidden; some of them
must be visible (parameter HIDDENCH).
0095 'An axis cannot be MASTERAXIS of several Gantry pairs'
DETECTION During the validation of the machine parameters.
CAUSE There are two gantry axes with the same master axis.
SOLUTION Correct the configuration of the gantry axes.
0096 'A tandem axis must be velocity-Sercos'
DETECTION During the validation of the machine parameters.
CAUSE An axis of a tandem axis is not velocity-Sercos.
SOLUTION Both axes of a tandem axis must be velocity-Sercos.
0097 'Tandem/gantry pair eliminated because they were preceded by an empty pair'
DETECTION During the validation of the machine parameters.
CAUSE The gantry or tandem pairs of axes do not occupy consecutive positions in their
tables; there is an empty space or undefined position in one of them.
SOLUTION Gantry or tandem pairs of axes must occupy consecutive positions in the tables. If
there is an empty space in the table, i.e. an unassigned position, the CNC cancels
the pairs defined behind it.
0098 'The AXISEXCH parameter of the master and slave axes have been set differently'
DETECTION During the validation of the machine parameters.
CAUSE There is a gantry o tandem pair whose master and slave axes have parameter
AXISEXCH set differently.
SOLUTION Assign the same value to parameter AXISEXCH of both axes.
0099 'The value of PROBEFEED is too high to brake applying DECEL and JERK'
DETECTION During the validation of the machine parameters.
CAUSE The maximum probing feedrate (parameter PROBEFEED) is higher than the feedrate
needed to brake within the distance set by PROBERANGE with the acceleration and
jerk values of the axis.
SOLUTION The value of this parameter must be smaller than the feedrate needed to brake within
the distance set by PROBERANGE with the acceleration and jerk values of the axis.
The warning window shows the maximum feedrate that may be reached.
0100 'Too many variables waiting to be reported'
DETECTION During execution.
CAUSE The number of variables modified at the CNC that must be reported to the interface
exceeds the maximum admitted.
SOLUTION If the error persists, contact your supplier.