Error solving manual.
CNC 8060
CNC 8065
·15·
(REF: 1709)
0113 'Error when initializing user kinematics parameters'
DETECTION When activating a user kinematics.
CAUSE Error in the function for initializing the kinematics (UserTransforParamInit)
implemented in the file Kin_impl.c.
SOLUTION Check and correct the possible reasons why this function generates an error.
0116 'Error reading technological table'
DETECTION During the activation of a technological table.
CAUSE There is no technology table file cannot be found or the table has been modified (new
variables have been inserted, listed types have been modified and the CNC has not
been restarted).
SOLUTION Check the name of the table. If there is a table, restart the CNC.
0150 'Too many open files'
DETECTION While executing a part-program with global subroutines.
CAUSE The number of open files (main program plus external subroutines) is greater than 20.
SOLUTION Decrease the number of external subroutines open in the part-program at the same
time.
0151 'Writing access denied'
DETECTION When accessing a file.
CAUSE The CNC has tried to write in a file that does not have a writing permission.
SOLUTION Give the file writing permission.
0152 'The file cannot be opened'
DETECTION When accessing a file.
CAUSE The CNC could not open a file for reading or writing. The file does not have the proper
permissions, is not accessible or is corrupt.
SOLUTION Check that the file exists and that it has the proper permissions for the action to be
carried out (read/write). If the file is corrupt, its data has been lost.
0153 'Reading access denied'
DETECTION When accessing a file.
CAUSE The CNC has tried to read a file that does not have a reading permission.
SOLUTION Give the file reading permission.
0154 Protected program or routine'
DETECTION When accessing a file.
CAUSE The CNC has tried to read an encrypted file without having permission to read.
SOLUTION Contact the manufacturer of the machine to obtain the file encrypting codes.
0155 'The quick charge of the file is not possible'
DETECTION When accessing a file.
CAUSE The CNC has tried to read a file whose size is larger than the memory area assigned
for file quick charge.
SOLUTION Execute from RAM memory (subroutines with extension fst) only the files that are
called upon more often.
0160 'Axis/Set not available in the system'
DETECTION During execution.
CAUSE The possible causes are:
The instruction #SET AX or #CALL AX is trying to add to a channel an axis that
does not exist or is in another channel.
A parameter set that does not exist has been programmed in function G112.
SOLUTION Check the program. If the axis is in another channel, release it with the instruction
#FREE AX.
0165 'RT IT Overflow'
DETECTION During CNC operation.
CAUSE The real time interruptions exceed the allowed amount of time. Some possible causes
may be the installation of some device, driver or application that is incompatible with
the CNC.
SOLUTION If the error comes up often, it may be necessary to adjust the parameter LOOPTIME.
Analyze the cases where the error occurs and contact your supplier.