Error solving manual.
CNC 8060
CNC 8065
·41·
(REF: 1709)
1279 '" expected'
DETECTION During execution.
CAUSE Quote marks are missing in the programmed expression or instruction.
SOLUTION Check the program.
1281 ''The number of parameters and format indicators do not match'
DETECTION During execution.
CAUSE The number of data identifiers (%D or %d) appearing in the #MSG, #ERROR or
#WARNING instruction does not match the number of parameters to be displayed.
SOLUTION Check the program.
1282 'Message too long'
DETECTION During execution.
CAUSE The text message of the instruction #MSG, #ERROR or #WARNING is too long.
SOLUTION It may have up to 69 characters, including the characters that replace the data
identifiers.
1283 'Too many format indicators'
DETECTION During execution.
CAUSE There are more than 5 data identifiers (%D ó %d) in the instruction #MSG, #ERROR,
#WARNING.
SOLUTION Reduce the number of data identifiers.
1284 'Arithmetic expression expected'
DETECTION During execution.
CAUSE There are data identifiers (%D ó %d) in the instruction #MSG, #ERROR, #WARNING,
but the parameters to be displayed are missing.
SOLUTION Check the program.
1285 'Tool radius written twice'
DETECTION During execution.
CAUSE The tool radius has been programmed more than once in the same block.
SOLUTION Program the tool radius only once in the block.
1286 'Tool length written twice'
DETECTION During execution.
CAUSE The tool length has been programmed more than once in the same block.
SOLUTION Program the tool length only once in the block.
1287 '"[" expected'
DETECTION During execution.
CAUSE The opening bracket "]" is missing in the programmed expression or instruction.
SOLUTION Check the program.
1288 'Too many parameters programmed in the instruction'
DETECTION During execution.
CAUSE The syntax of the instruction is wrong.
SOLUTION Check the program.
1290 'I, J, K coordinates programmed wrong'
DETECTION During execution.
CAUSE The possible causes are:
The programmed values for the center of the circular interpolation, Polar origin
or center of rotation of the coordinate system are too high.
The values programmed for the center of the circular interpolation, being G264
active, are wrong.
SOLUTION Check the program.
1291 'No more S functions allowed'
DETECTION During execution.
CAUSE There are too many S functions in the same block.
SOLUTION The maximum number of S functions allowed in the same block is 4.

Related product manuals